Sysmac Industrial IDE

A truly integrated development environment for machine automation, combining configuration,
programming, simulation, and monitoring in a simple interface.

It Has Never Been Easier To Try Out Sysmac

The “One Software” Sysmac Bundle

IDE Sysmac Studio SYSMACAD201L
CPU NX502-1300 CPU NX5021300
PSU S8VK-G06024 Book Type Power Supply S8VKG06024

The “One Connection” Sysmac Bundle

IDE Sysmac Studio Lite SYSMACLE201L
CPU NX102-9020 Modular CPU NX1029020
Power Supply S8VK-G06024 Book Type Power Supply S8VKG06024
IPC Omron IPC NYB6540530

The “One Controller” Sysmac Bundle

IDE Sysmac Studio SYSMACBA201L
CPU NX102-9020 Controller NX1029020
PSU S8VK-G06024 Book Type Power Supply S8VKG06024
Safety NX-SL5500 Safety Controller NXSL5500
Safety IO NX-SID800 Safety IO NXSID800
Local IO (1) NX-ID4442 Local IO NXID4442
Local IO (2) NX-OD4256 Local IO NXOD4256
Coupler NX-ECC202 Coupler NXECC202

Where do I get Started with Sysmac?

Chase Myles of Omron has a great up and running series on YouTube.

How can the Programmable Controller "SYSMAC" be connected to a personal computer through a serial port or an Ethernet? Is the FinesGateway necessary?
In the case of serial interface

There are two ways: using the FinsGateway Ver.3 or not using it.

In the case when an application to be developed with the VisualC++ or the VisualBasic may be used through other interface methods, it is better to utilize the FinsGateway Ver.3.

On the other hand, in the case when the connection is done only through a higher-level link, it is possible to open a COM port directly from the VisualC++ or to issue a higher-level link command disclosed in the manual by using the VisualBasic and the ActiveX Control for commercially available serial access without using the FinsGateway Ver.3.

In the case of Ethernet interface

There are two ways: using the FinsGateway Ver.3 or not using it.
In the case when an application to be developed with the VisualC++ or the VisualBasic may be used through other interface methods, it is better to utilize the FinsGateway Ver.3.

On the other hand, in the case when the connection is done only through an Ethernet interface, it is possible to call up the WinSock2 library directly from the VisualC++ or to issue FINS/UDP/IP commands disclosed in the manual by using the VisualBasic and the ActiveX Control for commercially available WinSock2 without using the FinsGateway Ver.3.

How can we convert SYSMAC Support Software file SP1 by CX-Programmer FA Integrated Tool Package?
After CX-Programmer Ver.2.1

Able to read it directly.

Select the FILE OPEN function on menu, then we can save as SP1 file: SYSMAC support soft ladder program (*SP1).

Before CX-Programmer Ver.2.1

File Conversion Utility convert SP1 file specifying CXT file to read SP1 File.

Then we can save as CXT file. Then we can open CXT file by CX-Programmer.

Automotive Case Study

Omron’s Sysmac integrated automation platform is a tool to meet these objectives. The Sysmac platform includes powerful machine automation controllers (MACs), intuitive human machine interfaces (HMIs), and fast networking via EtherCAT or Ethernet/IP. These complementary technologies support a range of advanced functions, including motion, safety, vision and robotics.

 

Learn More

Who is Mechatronic Solutions?

Mechatronic Solutions is a distributor of OMRON automation products and solutions for Minnesota, Wisconsin, North Dakota, and South Dakota. We have a team of technical experts on staff to help select the right automation products for your application. If you have any questions or would like to speak with a member of our team, contact us at (763) 447-3407 or fill in the Contact Form.

Why Sysmac?

Created to give machine developers complete control from a single environment, Sysmac Studio integrates configuration, programming, simulation, and monitoring in a simple interface. This advanced software tool is the sole software required for the NJ-Series machine automation controller, which brings together logic, motion, and vision onto a single platform.

Name(Required)
This field is for validation purposes and should be left unchanged.

Feasibility Testing

Proof of concept or feasibility testing is an important part of Mechatronic’s approach to providing high quality solutions and exceptional results for our customer’s automation projects. Mechatronic Solutions has an experienced team of Application Engineers and an Automation Solutions Center with extensive demo equipment to conduct testing.

Learn More

Some of Omron’s Sysmac Hardware

  • NX-series controllers
  • NJ-series controllers
  • NA-series HMI
  • NX-series I/O and safety
  • G5-series servo
  • MX2-series and RX-series frequency inverter
  • FH and FQM vision system and sensor
  • GX network components
  • E3 N-Smart sensors
  • ZW-series measurement sensors

CONTACT MECHATRONIC SOLUTIONS TODAY

Need engineering work and feasibility testing in Minnesota, Wisconsin, North Dakota, or South Dakota… Call Mechatronic Solutions at 763-447-3407 or fill in the Contact Us form today to work with our application engineers or schedule a demo.